Blue Rhodium Plating Solution – RH4BLUE

Posted on May 29, 2017 By

WARNING: The video has been developed for demonstration purposes before starting operation, please read the data sheet or consult one of our experts. Rhodium blue by galvanic bath treatment conditions Voltage: 1.5 to 2.2 Volts Temperature: 25 ° C Variable necessary galvanic Anode Material Used by Titanium / Platinum Demineralised water 1 liter flask RH4FBLUE – Concentrated formula Step 1: preparation of the solution ready for use from concentrate important Note: for solutions ready for use, start from step 2 Start with 500 ml of demineralized water and add the constitutive solution Collect the remaining rhodium and bring the water content by volume Close the flask and mix well the solution is now ready for use Step 2 Prepare the part following the procedure suitable wash Step 3: machine Configuration Operating at 1.5 to 2 volts at room temperature Step 4: the deposition process Blue Rhodium is an intermediate stage of the oxidation process the processing time changes depending on the size of the piece to treat the color will change gradually r from Dorado, in Brown Purple and in the end, Blue Let’s take a closer look [accelerated Sequence] Step 5: Rinse and then dry the part with compressed air Final Result If you have questions or problems, please contact us at: plating @ legor.com or visit: www.legorgroup.com

As found on Youtube

Originally posted 2017-03-19 20:39:15.